FUEL SYSTEM
Disconnect the IAC valve 2P connector (1).
Remove the three bolts (8 × 35 mm) (1), two bolts (8 ×
35 mm) (2), two nuts (3) and intake manifold (4).
• If the stud bolt (5) became loose during intake
manifold removal, tighten them so that the stud bolt
height above the injector base surface is as
specified.
STANDARD: 31 mm (1.2 in)
5-88
(1)
(3)
(4)
(2)
(1)
(5)