LEFT CONTROL HANDLE WITH NO BOOM
CONTROL
Op. 29 100 10
REMOVAL
1. Securely latch the seat in the raised and latched
position. Remove the step shield and front step
cover to access the control handle, linkage and
valve area.
2. Disconnect the hydrostatic pump control link, 1.
3. Remove the handle mounting bolts, 1, and re-
move the handle assembly from the unit.
DISASSEMBLY
1. Loosen the boot securing bolts, 1, and slide the
boot, 2, off the handle.
2. Remove the roll pin, 3, and shim washers, 4.
Take note of the number and position of all shim
washers for reassembly.
3. Remove the bearings, 5, from the handle, retain-
ing any shim washers at 6.
4. Slide the handle sideways and remove from the
stub shafts.
SECTION 29 - HYDROSTATIC TRANSMISSION
29-81
1
4802-10
1
Copyright © New Holland
172
1
1
173
2
5
4
3
174