5. Boom control valve spool in the neutral (cen-
tered) position.
6. Remove the rear boom hydraulic line, 1, and cap
the line. Install the hydraulic hand pump and
pressure gauge to the rear port in the control
valve.
7. Using the hand pump, build pressure against the
circuit relief valve and monitor the pressure
gauge to read the pressure at the point the relief
valve starts to open.
CAUTION
Do not increase pressure over 3800 PSI. If the re-
lief valve does not open when pressure reaches
3600 PSI, discontinue the test and replace the
valve.
8. If there is an operational complaint and the boom
circuit relief valve releases pressure under 235
bar (3400 PSI), replace the valve, 1. If the valve
does not release pressure by 248 bar (3600 PSI),
also replace the valve. All replacement boom cir-
cuit relief valves are set at 241 bar (3500 PSI)
and are not adjustable.
SECTION 35 - HYDRAULIC SYSTEM
35-33