Op. 35 724 54
DISASSEMBLY AND INSPECTION
Main System Relief Valve
The non-serviceable, non-adjustable, cartridge- type
main system relief valve, 1, is set at 170 - 177 bar
(2500 - 2600 PSI). The relief valve should not be re-
placed with a valve of a higher pressure setting, as
structural damage to the boom and/or main frame or
internal damage to hydraulic system may occur.
CAUTION
Component failure from high hydraulic pressure
could result in injury.
Lift Check Valves
There is a check valve in each circuit - bucket, boom,
and auxiliary.
The only time the check valves serve a function is af-
ter the control spools have been shifted. If the valves
are operating properly, they prevent any movement
of either the boom or bucket until pressure opens the
lift checks.
Inspect the lift check components for damage to the
seat, 1, spring, 2, or cap, 3.
Op. 35 724 90
Spool Locks (Boom and Bucket)
Remove the solenoid plunger assemblies, 1, from
the ports, 2, over the control spool ends.
SECTION 35 - HYDRAULIC SYSTEM
19984465
19984466
19984467
35-44
1
2
1
2
1
Copyright © New Holland
46
3
47
48