New Holland LS140 Workshop Manual page 582

Hide thumbs Also See for LS140:
Table of Contents

Advertisement

Electric Solenoid
The following tests should be performed with the
motor removed from the starter assembly.
Each test should not last more than 3 - 5 seconds to
avoid overheating the solenoid.
Tests should be performed with a fully charged
12 volt battery.
Pull-in Test
Connect a lead from the positive battery post to the
spade terminal, 1, (starter switch wire) on the
solenoid. Connect a lead from the battery negative
post to the solenoid housing, 2.
Touch a second negative lead to the heavy solenoid
terminal leading to the field coil, 3. This completes the
circuit through both the pull-in and hold-in coil
windings. The pinion should jump forward.
Remove the negative lead from the field coil terminal,
3. The pinion should stay extended, held by the
hold-in coil.
Remove the positive lead from the spade terminal.
The pinion should retract immediately.
If the solenoid fails to perform as described, replace
it.
SECTION 55 - ELECTRICAL SYSTEM
SM463-216
SM463-217
55-157
1
2
3
1
2
3
Copyright © New Holland
234
235

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ls150

Table of Contents