All grounding locations should be checked for tight
hardware and absence of paint between parts for
good connecting, as follows:
1. Check the grounding strap from the engine to
main frame, 1.
2. Check the wiring harness from the EIC to the bell
housing.
3. Check the grounding strap from the cab ROPS
structure to main frame, 1.
On the grounding strap from the ROPS to the
main frame, be sure the strap is attached
between the ROPS and the main frame (yellow
lower frame). DO NOT attach the strap between
the cab interliner (cab side screen sections) and
the main frame, as the cab interliner on these
skid steers is rubber-mounted to the ROPS and,
therefore, insulated from the ROPS. However, a
second strap may be added between the cab
interliner and the main frame and should cause
no ill effect.
4. Check the wiring harness grounds to the bell
housing, 1.
NOTE: When attaching multiple ground wires,
always place the heaviest ground wire (battery
ground cable) next to the ground surface (bell
housing). Stack the remaining ground wires
according to wire size, largest on the bottom and
smallest last. Two wires in a terminal are considered
to be larger than a single wire of the same size.
SECTION 55 - ELECTRICAL SYSTEM