Gear Pump Flow Efficiency Test - New Holland LS140 Workshop Manual

Hide thumbs Also See for LS140:
Table of Contents

Advertisement

GEAR PUMP FLOW EFFICIENCY TEST

Fittings and gauges required:
1. Hydraulic flow tester - 115 l/min (30 GPM) capac-
ity.
2. Male and female 1/2" quick couplers for units
equipped with auxiliary boom hydraulics.
3. Two male 3/4" UNF 37 flare to tester fittings for
units without auxiliary boom hydraulics.
Test Procedure
Gear pump flow test with units equipped with auxilia-
ry boom hydraulics.
1. Lower the boom and bucket to the lowered posi-
tion, resting on the ground.
2. Stop engine, turn ignition key to the run position
and operate the boom and bucket control pedals
to relieve pressure in the cylinders. Turn off the
key.
3. Attach the pressure (inlet) hose from the flow
tester with the female quick coupler to the male
half on the loader at 1.
4. Attach the return (outlet) hose from the flow test-
er with the male coupler to the female half on the
loader at 2.
IMPORTANT: Make sure the flow tester is connected
into the hydraulic system properly for proper oil flow
through the tester to prevent damage to the hydraulic
test equipment or hydraulic system.
CAUTION
Never position tester between the gear pump and
control valve as the system relief valve will be out
of the test circuit, and pump over pressure may
cause a pump failure by splitting the center sec-
tion or twisting off the input shaft.
SECTION 35 - HYDRAULIC SYSTEM
35-34
Copyright © New Holland
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ls150

Table of Contents