Ground Side Voltage Drop Test
1. Ensure the key start switch is in the off position.
2. Test connections are the same as the previous
test except that the voltmeter, 3, is now
connected between the negative post of the
battery and the alternator frame. Connect the
voltmeter negative lead to the alternator frame.
NOTE: Ensure the variable rate load tester, 5, is set
to the minimum current draw position.
3. Start the engine and increase the speed to 2000
RPM.
4. Slowly increase current draw until the ammeter,
2, reads 40 amps.
5. When the ammeter reads 40 amps, the voltmeter
should not read more than 0.2 volts.
If the reading is in excess of 0.2 volts, there is a
high resistance fault in the ground side of the
circuit.
If the maximum output reading obtained is less
than 40 amps and voltage drop is within
specifications, the alternator is faulty. Conduct
the alternator component tests outlined in this
section.