Field Coil
Inspect the field coil for an open circuit with a
continuity tester. Replace the motor housing if there
is no continuity between the two brushes.
Inspect the field coils for short to ground with a
continuity tester. If any continuity is noted between
the brush and motor housing, locate the fault in the
insulation, and repair or replace the motor housing as
appropriate.
Check field poles and coils for tightness. Replace the
motor housing if loose or improperly seated coils are
detected.