Bench Check
To check the alternator on a test bench, proceed as
follows:
1. Connect the alternator as shown, except leave
the load resistor disconnected.
2. Slowly increase the alternator speed and
observe the voltage.
3. If the voltage is uncontrolled with speed, and
increases above 15.5 V, check the regulator.
4. If voltage is below 15.5 V, connect the load
resistor as shown.
5. Operate the alternator at 2500 RPM and adjust
the load resistor as required to obtain maximum
output.
6. Measure the output current. The output must be
within the limits shown in the section on "Service
Specifications." If the output is less than the
specified value, disassemble and check the
alternator.
IMPORTANT:
1. Reversed battery connections will damage the
alternator and/or wiring.
2. When connecting a booster battery, make certain
to connect the negative battery terminals
together and the positive battery terminals
together.
3. When a fast charger is used to charge the
battery, disconnect the equipment battery
cables.
4. Grounding of the alternator output terminal will
damage the alternator and/or circuit.
5. Do not connect a load of over 1A to the L terminal.
6. If the alternator is operated with terminals L and
B short-circuited, it may damage the diode trio.