Electrical test procedure:
1. Lower the boom and attachment to the ground or
remove any attachment, raise the boom, and rest
the boom on the boom lock pins at 1.
2. Raise the seat and latch securely in the raised
latch position, 1. Remove the step shield, 2, from
over the control valve to access the solenoid
locks.
CAUTION
Do not work under raised seat unless securely
latched in the raised position.
3. Unplug the solenoid, 1, one at a time, and check
for battery voltage at the main wire harness
plugs, pink/light-blue and black wires. The oper-
ator must be in the seat with the seat belt buckled
and the ignition key in the "ON" position.
NOTE: If both solenoids are unplugged, the EIC will
show an F0A code and there will be no voltage from
the EIC to the solenoids.
4. If there is battery voltage at the solenoids, re-
move the coils and check their operation. If the
plunger moves in when power is applied, check
for binding when the coil is threaded into the
body. Check for spool centering to allow the coil
plunger to seat into the groove in the spool.
DANGER
If the lockout solenoids are loosened or removed
from the control valve body, the pedal(s) are no
longer locked. Pedal or hand control movement
will result in spool movement and boom/bucket
movement.
SECTION 35 - HYDRAULIC SYSTEM