REINSTALLATION
1. Lubricate the flex plate splines, 1, and pump
splines with MOLY COATE GN PASTE or
NEVER SEIZE.
2. Reinstall the pump assembly to the engine
bellhousing. Align the spline pump shaft with the
drive coupler. Do not force the shaft into the drive
coupler. Secure with two 1/2" x 1-1/4" cap screws
and two lock washers at 2, torque to 61 N·m (45
ft. lbs.). With the pump assembly attached, now
install the pump support plate, 3, to the
bellhousing at 4, and to the pump assembly at 5,
and torque to 40 N·m (30 ft. lbs.).
3. After installation of the pump assembly, 1, and
pump support plate, 2, to the engine bell housing,
install the attaching bolts, 3.
4. If a unit is experiencing leakage between the
pump backplate and housing at 4, loosen the
attaching bolts and check for a gap. Shim if
required.
5. Install the keys in slots on the trunnion shafts, 1,
and assemble cam arms, 2, onto shafts. Secure
with 3/8" x 2-1/2" Grade 8 cap screws, lock
washers and nuts at 3, torque to 65 N·m (48 ft.
lbs.). Position the cam arms, 2, flush or 1/32"
below the trunnion shafts at 4.
6. Reinstall hydraulic lines and tighten securely.
When tightening fittings, first align hoses and
tubes for clearance and tighten to seat to fittings,
then loosen and retorque.