3 Maintenance

3.4.4 Replacing the battery pack

3.4.4 Replacing the battery pack

Location of battery pack

The battery pack for the measurement system is located inside the base of the
robot, as shown in the figure below.
xx0500001390
A
Continues on next page
144
Note
The battery low alert (38213 Battery charge low) is displayed when the battery
needs to be replaced. The recommendation to avoid an unsynchronized robot
is to keep the power to the controller turned on until the battery is to be replaced.
For an SMB board with 3-pole battery contact (RMU101 3HAC044168-001 or
RMU102 3HAC043904-001), the lifetime of a new battery is typically 36 months.
For an SMB board with 2-pole battery contact, the typical lifetime of a new battery
is 36 months if the robot is powered off 2 days/week or 18 months if the robot is
powered off 16 h/day. The lifetime can be extended for longer production breaks
with a battery shutdown service routine. See Operating manual - IRC5 with
FlexPendant for instructions.
WARNING
See instructions for batteries,
Base cover, including gasket. Battery pack is located beneath the cover.
© Copyright 2006-2018 ABB. All rights reserved.
Safety risks during handling of batteries on page
Product manual - IRB 1600/1660
37.