5 Calibration
5.4.4 Axis Calibration - Running the calibration procedure
Continued
Situation
The RobotWare program is terminated with
PP to Main.

Axis Calibration with SafeMove option

To be able to run Axis Calibration SafeMove needs to be unsynchronized. The Axis
Calibration routine recognizes if the robot is equipped with SafeMove and will force
SafeMove to unsynchronize automatically.
However, SafeMove may generate other warning messages anytime during the
Axis Calibration routine.

Safety controller not synchronized - SafeMove message

1
2
3
Continues on next page
362
Action
SafeMove generates the message "Safety control-
ler not synchronized".
xx1500002480
Confirm unsynchronized state by pressing Ac-
knowledge to continue Axis Calibration proced-
ure.
Restart Axis Calibration procedure by pressing
Play.
© Copyright 2006-2018 ABB. All rights reserved.
Action
Remove the calibration tool, if it is installed,
and restart the calibration procedure from
the beginning. See
Starting the calibration
procedure on page
360.
If the calibration tool is in contact the robot
axis needs to be jogged in order to release
the calibration tool. Jogging the axis in wrong
direction will cause the calibration tool to
break. Directions of axis movement is shown
in
Calibration movement directions for all
axes on page 344
Note
Product manual - IRB 1600/1660
3HAC026660-001 Revision: W