ABB IRB 1660 Product Manual page 306

Table of Contents

Advertisement

4 Repair
4.6.9 Replacement of motor, axis 5, IRB 1660ID
Continued
15
16
17
18
Continues on next page
306
Action
Remove the attachment screws securing
the cable harness bracket to the upper arm
tube.
Pull carefully out the upper arm tube a little.
Not more than it is possible to reach the
connectors for motor axis 5.
CAUTION
Be careful not to damage the cable harness
in the process. The space is cramp.
Disconnect connectors R4.MP5 and R4.FB5
to motor axis 5.
Remove the upper arm tube with the cable
harness to motor axis 6.
CAUTION
Be careful not to damage the cable harness
to motor axis 6 in the process.
© Copyright 2006-2018 ABB. All rights reserved.
Information
xx1500001267
A: Attachment screws (2 pcs)
R4.FB5
R4.MP5
xx1400002576
Product manual - IRB 1600/1660
3HAC026660-001 Revision: W

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 1600

Table of Contents