5.6 Verifying the calibration

Introduction
Always verify the results after calibrating any robot axis to verify that all calibration
positions are correct.
Verifying the calibration
Use this procedure to verify the calibration result.
1
2
3
4
Product manual - IRB 1600/1660
3HAC026660-001 Revision: W
Action
Run the calibration home position program twice.
Do not change the position of the robot axes after running
the program!
Adjust the synchronization marks when the calibration is
done, if necessary.
Write down the values on a new label and stick it on top
of the calibration label.
xx
Remove any calibration equipment from the robot.