11
12
13
14
15
16
17
18
19
20
Product manual - IRB 1600/1660
3HAC026660-001 Revision: W
Action
Apply the same load in the opposite direc-
tion (180°), as shown in the figure.
Remove the load and make a note of the
value from the dynamometer, as value a2.
Calculate the play in the axis as a1 + a2.
The values of a1 and a2 are absolute val-
ues.
Turn on power.
Turn axis 5 to +90°.
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot
working area.
Repeat
step 10
to
step
12.
Turn on power.
Turn axis 5 to -90°.
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot
working area.
Repeat
step 10
to
step
12.
© Copyright 2006-2018 ABB. All rights reserved.
4.4.12 Measuring the play 1600ID/1660ID, axis 5
Information
xx1500000315
The maximum play allowed is:
IRB 1600ID-4/1.5: 0.34 mm
IRB 1660ID-X/1.55: 0.25 mm
4 Repair
Continued
235