4 Repair
4.6.12 Replacement of motor, axis 6, IRB 1660ID
Continued
8
9
Continues on next page
326
Action
Remove the two short screws used to tem-
porarily secure the cover.
Apply locking liquid to the assembly surface
on the upper arm tube.
© Copyright 2006-2018 ABB. All rights reserved.
Information
xx1500003257
A: Short screws (2 pcs)
B: Cover
The locking liquid is specified in
equipment on page
319.