3HAC026660-001 Revision: W
Action
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the ro-
bot working area.
Remove the AW equipment from
the upper arm.
Disconnect connectors R4.FB5 and
R4.MP5, from the back.
Remove the VK- Cover to access
the cable connections inside the
arm.
Gently pull the cables out of the
upper arm.
© Copyright 2006-2018 ABB. All rights reserved.
4.6.8 Replacement of motor, axis 5, IRB 1600ID
Note
Shown in section
Remove AW Gun on page 229
xx0700000080
A R4.FB5
xx0700000054
A VK-Cover
4 Repair
Continued
Continues on next page