ABB IRB 1660 Product Manual page 202

Table of Contents

Advertisement

4 Repair
4.4.4 Replacing the wrist unit, IRB 1600
Continued
Equipment, etc.
Other tools and pro-
cedures may be re-
quired. See refer-
ences to these pro-
cedures in the step-
by-step instructions
below.
Deciding calibration routine
Decide which calibration routine to be used, based on the information in the table.
Depending on which routine is chosen, action might be required prior to beginning
the repair work of the robot, see the table.
1
Removal, wrist unit
The procedure below details how to remove the complete wrist unit.
1
Continues on next page
202
Spare part no.
CAUTION
Always cut the paint with a knife and grind the paint edge when disassembling
parts. See
Cut the paint or surface on the robot before replacing parts on page
Action
Decide which calibration routine to use for
calibrating the robot.
Reference calibration. External cable
packages (DressPack) and tools can
stay fitted on the robot.
Fine calibration. All external cable
packages (DressPack) and tools
must be removed from the robot.
If the robot is to be calibrated with refer-
ence calibration:
Find previous reference values for the axis
or create new reference values. These val-
ues are to be used after the repair proced-
ure is completed, for calibration of the ro-
bot.
If no previous reference values exist, and
no new reference values can be created,
then reference calibration is not possible.
If the robot is to be calibrated with fine
calibration:
Remove all external cable packages
(DressPack) and tools from the robot.
Action
Decide which calibration routine to use, and
take actions accordingly prior to beginning
the repair procedure.
© Copyright 2006-2018 ABB. All rights reserved.
Art. no.
Note
These procedures include refer-
ences to the tools required.
Note
Follow the instructions given in the refer-
ence calibration routine on the FlexPendant
to create reference values.
Creating new values requires possibility to
move the robot.
Read more about reference calibration for
Axis Calibration in
Reference calibration
routine on page
350.
Read more about reference calibration for
Pendulum Calibration in Operating manu-
al - Calibration Pendulum.
Note
Product manual - IRB 1600/1660
3HAC026660-001 Revision: W