Unsynchronized speed exceeded - SafeMove message while saving robot data
1
2
3
Unsynchronized time limit expired - SafeMove message anytime during Axis Calibration routine
1
2
3
Product manual - IRB 1600/1660
3HAC026660-001 Revision: W
5.4.4 Axis Calibration - Running the calibration procedure
Action
SafeMove generates the message "Unsynchron-
ized speed exceeded" while saving robot data.
xx1500002481
Press Acknowledge to continue Axis Calibration
procedure.
Restart Axis Calibration procedure by pressing
Play.
Action
SafeMove generates the message "Unsynchron-
ized time limit expired" (anytime).
xx1500002482
Press OK to continue Axis Calibration procedure.
Restart Axis Calibration procedure by pressing
Play.