System Configuration - Mitsubishi Electric GOT2000 Series Connection Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

12.2 System Configuration

12.2.1
Connecting with CC-Link Ver.1 compatible
PLC
Model name
MELSEC iQ-R Series
Motion controller CPU (MELSEC
iQ-R Series)
C Controller module (MELSEC
iQ-R Series)
CNC C80
CR800-R(R16RTCPU)
MELSEC-Q
(Q mode)
C Controller module
(Q Series)
Motion controller CPU (Q Series)
CNC C70
Robot controller (CRnQ-700)
MELSEC-L
MELSEC-L
(L26CPU-BT)
MELSEC-QnA
MELSEC-A
*6
MELSEC iQ-F series
*7
MELSEC-FX
*1
For the system configuration of the CC-Link module, refer to the following manuals.
*2
For the specifications and inquiries of the CC-Link dedicated cable, refer to the following.
*3
The maximum overall extension cable length and the length between stations vary depending on the cable type to be used and
the transmission speed.
For details, refer to the following manual.
*4
Transient transmission can be performed to only CC-Link modules of function version B or later and software version J or later.
*5
Specify Ver.1 as the mode setting in the Communication Settings to use it.
For details of the settings, refer to the following the manual.
*6
When using an FX3U-16CCL-M with the MELSEC iQ-F series, bus conversion module (FX5-CNV-BUS or FX5-CNV-BUSC) is
required.
*7
MELSEC-FX do not support FX5-CCL-MS.
*8
GT25-W, GT2505-V does not support the option device.
CC-Link
module
Connection cable
PLC
Communication
*1
CC-Link module
type
RJ61BT11
QJ61BT11
QJ61BT11N
CC-Link (Ver.1)
LJ61BT11
-
AJ61QBT11
*4
A1SJ61QBT11
AJ61BT11
*4
A1SJ61BT11
FX3U-16CCL-M
FX5-CCL-MS
CC-Link System Master/Local Module User's Manual QJ61BT11N
Control & Communication Link System Master/Local Module Type AJ61QBT11/A1SJ61QBT11 User's Manual
Control & Communication Link System Master/Local Module Type AJ61BT11/A1SJ61BT11 User's Manual
MELSEC-L CC-Link System Master/Local Module User's Manual
CC-Link Partner Association's home page: http://www.cc-link.org/
CC-Link System Master/Local Module User's Manual QJ61BT11N
Control & Communication Link System Master/Local Module Type AJ61QBT11/A1SJ61QBT11 User's Manual
Control & Communication Link System Master/Local Module Type AJ61BT11/A1SJ61BT11 User's Manual
MELSEC-L CC-Link System Master/Local Module User's Manual
FX3U-16CCL-M USER'S MANUAL
12.3.1 Setting communication interface (Controller Setting)
GOT
Connection cable
Max.
Cable model
Option device
distance
CC-Link
GT15-J61BT13
dedicated cable
*3
*2
12.2 System Configuration
Communication driver
CC-Link Ver2(ID)
GOT
Number of
connectable
*8
Model
equipment
26 GOTs
*5
8 GOTs
12 - 9
12

Hide quick links:

Advertisement

Table of Contents
loading