Communication Detail Settings - Mitsubishi Electric GOT2000 Series Connection Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

8.3.2

Communication detail settings

■1. Bus(Q)
Item
Number of Stages
Slot No.
*3
Monitor Speed
Timeout Time (Sec.)
Servo axis switching GD device
head No.
*1
This range is effective when collecting a large amount of data (such as logging and recipe function) on other than the monitor
screen.
However, the range may affect the sequence scan time when connecting to Q00UJ/Q00U/Q01U/Q02UCPU or Q00J/Q00/
Q01CPU.
If you want to avoid the influence on the sequence scan time, do not set [High(Normal)].
(This setting hardly affects QCPUs other than the above.)
*2
Set this range if you want to avoid the influence on the sequence scan time further than the [Middle] setting when connecting to
Q00UJ/Q00U/Q01U/Q02UCPU or Q00J/Q00/Q01CPU.
However, the monitor speed may be reduced.
*3
When using a global label, to read or write more than 235 two-byte characters, set the [Monitor speed] to [High (Standard)] or
[Middle].
If [Monitor speed] is set to [Low], a system error occurs when reading or writing.
For details, refer to the following manual.
■2. Bus(A/QnA)
Item
Number of Stages
Slot No.
Timeout Time (Sec.)
(Default: 1)
(Default: 0)
Set the monitor speed of the GOT.
This setting is not valid in all systems. (Default: Normal)
Set the time period for a communication to time out. (Default: 12)
Set the servo axis switching GD device head No. (Default: 10)
For details, refer to the following POINT.
(4) Indirect specification of the servo axis No.
GT Designer3 (GOT2000) Screen Design Manual
(Default: 1)
(Default: 0)
Set the time period for a communication to time out. (Default: 3)
POINT
POINT
POINT
(1) Communication interface setting by Utility
The communication interface setting can be changed on the Utility's [Communication
Settings] after writing [Controller Setting] of project data.
For details on the Utility, refer to the following manual.
GOT2000 Series User's Manual (Utility)
(2) Precedence in communication settings
When settings are made by GT Designer3 or the Utility, the latest setting is effective.
(3) When changing Stage No. and Slot No.
Change these settings with the PLC CPU turned OFF, and then reapply the power to the PLC
CPU and GOT.
Failure to do so may generate a system alarm (No.487).
(4) Indirect specification of the servo axis No.
When the servo axis No. is specified to 100 to 115 in GT Designer3, the servo axis number
Description
Description
8.3 GOT Side Settings
Range
1 to 7
0 to 9
*1
*2
High (Normal)
/Middle/Low
12 to 90
0 to 65520
Range
1 to 7
0 to 7
3 to 90
8 - 33
8