■2. When connecting the GOT and the personal computer by Ethernet
PLC
Varies according to
the connection type.
PLC
Connection type
For the system configuration between the
GOT and PLC, refer to the following.
ETHERNET CONNECTION
For the system configuration between the
GOT and PLC, refer to the following.
SERIAL COMMUNICATION
CONNECTION
For the system configuration between the
GOT and PLC, refer to the following.
CC-Link IE CONTROLLER
NETWORK CONNECTION
CC-Link IE FIELD NETWORK
CONNECTION
For the system configuration between the
GOT and PLC, refer to the following.
DIRECT CONNECTION TO CPU
SERIAL COMMUNICATION
*4
CONNECTION
For the system configuration between the
GOT and PLC, refer to the following.
*3
BUS CONNECTION
*1
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver, or other system equipment corresponding to the applicable Ethernet network
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standards.
A cross cable is available for connecting the GOT to the Ethernet module.
*2
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
*3
LCPU is not applicable to the bus connection.
GOT
GOT
Model
Interface
- (Built into
GOT) or
GT25-
J71E71-
*5
100
- (Built into
GOT) or
GT25-
J71E71-
100
*5
- (Built into
GOT) or
GT25-
J71E71-
*5*6
100
*4
- (Built into
GOT) or
*5
GT25-
J71E71-
100
*5*6
PC
Connection cable
*1
Connection cable
Cable model
Twisted pair cable
• 10BASE-T
Shielded twisted pair cable
(STP) or unshielded twisted pair
cable (UTP): Category 3, 4, and
5
• 100BASE-TX
Shielded twisted pair cable
(STP): Category 5 and 5e
Twisted pair cable
• 10BASE-T
Shielded twisted pair cable
(STP) or unshielded twisted pair
cable (UTP): Category 3, 4, and
5
• 100BASE-TX
Shielded twisted pair cable
(STP): Category 5 and 5e
Twisted pair cable
• 10BASE-T
Shielded twisted pair cable
(STP) or unshielded twisted pair
cable (UTP): Category 3, 4, and
5
• 100BASE-TX
Shielded twisted pair cable
(STP): Category 5 and 5e
Twisted pair cable
• 10BASE-T
Shielded twisted pair cable
(STP) or unshielded twisted pair
cable (UTP): Category 3, 4, and
5
• 100BASE-TX
Shielded twisted pair cable
(STP): Category 5 and 5e
22.4 System Configuration
Communication driver
Connection type
dependant
Personal
Maximum
Number of
computer
segment
connectable
*2
equipment
length
Software
1 personal
100m
GX Works2
computer
for 1 GOT
GX Works3
1 personal
100m
MX Component
computer
MX Sheet
for 1 GOT
1 personal
GX Works3
100m
computer
GX Works2
for 1 GOT
GX Works2
Setting/
1 personal
100m
Monitoring tool
computer
for C Controller
for 1 GOT
module