5.2.4

Connection to CC-Link IE Field Network Ethernet Adapter Module

CC-Link IE Field
Network Master/
QCPU
Local module
Connection cable
PLC
*4
1)
CC-Link
IE Field
Model
Network
Cable
name
Master/
model
distance
Local
module
MELSEC-
Q
Double-
(Q mode)
QJ71G
shielded
F11-
twisted
Motion
*4
pair
T2
Controller
*3
cable
CPU
(Q Series)
*1
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver, or other system equipment corresponding to the applicable Ethernet network
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standard.
A cross cable is available for connecting the GOT to the Ethernet module.
*2
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
*3
Use cables with the following specifications.
*4
For the system configuration on the CC-Link IE Field Network module side, refer to the following manual.
CC-Link IE Field Network Ethernet Adapter Module User's Manual
*5
The number of connectable GOTs for one network is 63 units (at most).
*6
GT25-W, GT2505-V does not support the option device.
Connection cable 1)
CC-Link IE
Field Network
Ethernet adapter module
Max.
Communication
Model
type
name
NZ2G
100m
CC-Link IE
F-ETB
Connector
Category 5e or higher
Shielded RJ-45
CC-Link IE
Field Network
Ethernet adapter
module
Connection cable 2)
Connection cable 2)
Cable model
Communication
Connection
type
diagram
number
• 100BASE-TX
Shielded
twisted pair
cable (STP)
or unshielded
twisted pair
cable (UTP)
of category 5
or higher
Ethernet
• 10BASE-T
Shielded
twisted pair
cable (STP)
or unshielded
twisted pair
cable (UTP)
of category 3
or higher
Cable that satisfies the following specifications:
IEEE802.3 1000BASE-T
ANSI/TIA/EIA-568-B(Category 5e)
5.2 System Configuration
Communication driver
Ethernet(MITSUBISHI ELECTRIC),Gateway
GOT
*1
GOT
Number of
connectable
Maximu
Option
equipment
m
device
Model
segment
*6
*3
length
- (Built
into
GOT)
128 GOTs
(recommen
100m
ded to 16
units or
less)
GT25-
J71E71
-100
Range
5
*5
5 - 17