Mitsubishi Electric GOT2000 Series Connection Manual page 563

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

(6) Condition setting switches
Condition setting switches
OFF ON
SW
1
2
3
4
5
6
7
8
*1
The MELSECNET/10 network module can be communicated by default parameters.
For details, refer to the following manual.
For QnA/Q4AR MELSECNET/10 Network System Reference Manual
POINT
POINT
POINT
When the switch setting (other than the LED indication select switch) is changed
Turn the PLC CPU OFF then ON again, or reset the PLC CPU.
Setting
Description
switch
Network type
SW1
(PLC to PLC net-work (PC))
Station type
SW2
(Control station (MNG))
*1
Parameter for using
SW3
(common parameter (PRM))
SW4
*1
No. of stations
SW5
SW6
B/W
*1
Total BW points
SW7
SW8
Not used
: Necessary
9.5 PLC side setting when connecting to MELSEC/10
Setting necessity at GOT
Set value
connection
OFF (fixed)
ON (fixed)
OFF (fixed)
OFF (fixed)
OFF (fixed)
OFF (fixed)
: As necessary
: Not necessary
9
9 - 39