Mitsubishi Electric GOT2000 Series Connection Manual page 561

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

■2. Switch setting of MELSECNET/10 network module
Set for each setting switch.
AJ71QLP21
A
J71QLP21
RUN -
- POWER
PC -
- MNG
REMOTE -
- S.MNG
10
DUAL -
- D.LINK
SW.E -
- T.PASS
M/S.E -
-
100
PRM.E -
- CPUR/W
CRC -
- CRC
OVER -
- OVER
E
AB.IF -
- AB.IF
R
TIME -
- TIME
R
DATA -
- DATA
UNDER -
- UNDER
O
LOOP -
- LOOP
R
SD -
- SD
RD -
- RD
F.LOOP
NETWORK NO.
X100
X10
X1
GROUP NO.
STATION NO.
X10
X1
MODE
0: ONLINE(A.R)
2: OFFLINE
OFF
ON
PC
REMOTE
N.ST
MNG
PRM
D.PRM
STATION SIZE
(8.16.32.64)
LB/LW SIZE
(2.4.6.8K)
FRONT SIDE
IN
OUT
A1SJ71QLP21
A1SJ71QLP21
RUN
MNG
S.MNG
DUAL
D.LINK
T.PASS
F.E.
NETWORK
NO.
X100
(1)
X10
X1
(2)
GR.NO.
ST.NO.
X10
(3)
X1
(5)
MODE
MODE
0 : ONLINE(A.R)
2 : OFFLINE
FRONT SIDE
A1SJ71QLP21
(1) Network number setting switch
Network number
setting switch
NETWORK NO.
*1
Specify the same network No. as that of the GOT.
AJ71QLP21S
A
J71QLP21S
RUN -
- POWER
PC -
- MNG
REMOTE -
- S.MNG
1
10
1
DUAL -
- D.LINK
SW.E -
- T.PASS
M/S.E -
- EX.POWER
100
PRM.E -
- CPUR/W
CRC -
- CRC
OVER -
- OVER
E
E
E
AB.IF -
- AB.IF
R
R
R
TIME -
- TIME
R
R
DATA -
- DATA
R
UNDER -
- UNDER
O
O
O
LOOP -
- LOOP
R
R
R
SD -
- SD
RD -
- RD
R.LOOP
F.LOOP
R.LOOP
NETWORK NO.
X100
(1)
(1)
X10
X1
(2)
(2)
GROUP NO.
STATION NO.
(3)
X10
(3)
X1
(5)
(5)
MODE
0: ONLINE(A.R)
2: OFFLINE
OFF
ON SW
OFF
ON SW
OFF
ON
PC
REMOTE
1
1
N.ST
MNG
2
2
(6)
(6)
3
PRM
D.PRM
3
4
STATION SIZE
4
(8.16.32.64)
5
5
6
LB/LW SIZE
6
7
(2.4.6.8K)
7
8
8
24V
24G
FG
FRONT SIDE
IN
OUT
A1SJ71QLP21S
A1SJ71QLP21S
PW
CRC
‚d
PC
OVER
‚q
AB. IF
EXT.P W
REM.
‚q
SWE.
TIME
‚n
M/S.E.
DATA
‚q
PRM E.
UNDER
R.E.
SD
CPU R/W
RD
DISPLAY
(4)
L
R
(F.L)
(R.L.)
(1)
SW
OFF
ON
1
PC
REM.
(2)
2
N.ST
MNG
3
PRM
D.PRM
4
ST,SIZE
5
8,16,32,64
(3)
6
LB/LW SIZE
7
2,4,6,8k
8
EXT.PW
OFF ON
{24V
SW
C
1
2
3
(6)
24G
4
5
6
7
FG
8
IN
(5)
OUT
A1SJ71QLP21S
X100
X10
X1
9.5 PLC side setting when connecting to MELSEC/10
AJ71QBR11
A
J71QBR11
RUN -
- POWER
PC -
- MNG
REMOTE -
- S.MNG
10
1
- D.LINK
SW.E -
- T.PASS
M/S.E -
-
100
PRM.E -
- CPUR/W
CRC -
OVER -
E
AB.IF -
R
TIME -
R
DATA -
UNDER -
O
R
SD -
RD -
NETWORK NO.
X100
(1)
X10
X1
(2)
GROUP NO.
STATION NO.
X10
(3)
X1
(5)
MODE
0: ONLINE(A.R)
2: OFFLINE
OFF
ON
OFF
ON SW
PC
REMOTE
1
N.ST
MNG
2
(6)
PRM
D.PRM
3
STATION SIZE
4
(8.16.32.64)
5
LB/LW SIZE
6
(2.4.6.8K)
7
8
A1SJ71QBR11
PW
RUN
CRC
‚d
PC
MNG
OVER
‚q
S.MNG
REM.
AB. IF
‚q
DUAL
SWE.
TIME
‚n
D.LINK
M/S.E.
DATA
‚q
T.PASS
PRM E.
UNDER
F.E.
R.E.
SD
CPU R/W
RD
NETWORK
NO.
DISPLAY
(4)
X100
L
R
(F.L)
(R.L.)
(1)
X10
X1
SW
OFF
ON
1
PC
REM.
2
N.ST
MNG
(2)
3
PRM
D.PRM
GR.NO.
4
ST,SIZE
5
8,16,32,64
ST.NO.
6
LB/LW SIZE
X10
7
2,4,6,8k
(3)
8
X1
OFF ON
SW
(5)
C
1
MODE
2
3
(6)
MODE
4
0 : ONLINE(A.R)
5
2 : FOFFLINE
6
FRONT SIDE
7
8
IN
OUT
Description
Network No. setting
*1
(Network No.1)
: Necessary
A1SJ71QBR11
RUN
PW
CRC
‚d
MNG
PC
OVER
‚q
S.MNG
REM.
AB. IF
‚q
SWE.
TIME
‚n
D.LINK
M/S.E.
DATA
‚q
T.PASS
PRM E.
UNDER
SD
CPU R/W
RD
NETWORK
NO.
DISPLAY
(4)
X100
L
R
(F.L)
(R.L.)
X10
X1
SW
OFF
ON
1
PC
REM.
2
N.ST
MNG
3
PRM
D.PRM
GR.NO.
4
ST,SIZE
5
8,16,32,64
ST.NO.
6
LB/LW SIZE
X10
7
2,4,6,8k
8
X1
OFF ON
SW
C
1
MODE
2
3
(6)
MODE
4
0 : ONLINE (A.R)
5
2 : OFFLINE
6
7
8
A1SJ71QBR11
Setting necessity at GOT
Set value
connection
1
: As necessary
: Not necessary
9
9 - 37