Step 6.
Set the [CPU mode] and [Relay network No.] and [Relay station No.].
• When the target PLC has the same network No. as that of the GOT
Set the number assigned to the PLC that is targeted by using the transparent function and CC-Link
IE field network module.
• When the target PLC has a different network No. from that of the GOT
Set the number assigned the PLC that is used as a relay station and CC-Link IE field network
module.
Step 7.
Return [Transfer Setup], click [Other Station (Single Network)], and double-click [CC IE Field].
Step 8.
Set as shown below and click [OK].
• When the GOT and PLC are on the same network
Select [Access to CC IE Field module set on PLC side I/F].
• When the GOT and PLC are on the different networks
Select [Other station in the same loop or access to multilevel system] and set [Network No.] and
[Station No.].
MELSOFT GX Works3
Step 9.
The screen returns to the [Connection Channel Setup]. Click [Connection Test] to check if GX Works3
has been connected to the RCPU.
22.7 Personal Computer Side Setting