Got Ethernet Setting - Mitsubishi Electric GOT2000 Series Connection Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

1.1.2

GOT Ethernet Setting

The GOT can be connected to a different network by using the following network.
1) GOT IP Address Setting
Set the following communication port setting.
Standard port (When using GT25-W, port 1)
Set [GOT IP Address] and [Subnet Mask] in the standard port with a bult-in GOT, or port 1.
Extension port (When using GT25-W, port 2)
Set [GOT IP Address] and [Subnet Mask] in the extension port (the Ethernet interface for the Ethernet
communication module), or port 2 with a bult-in GOT.
When using the GOT other than GT25-W, BootOS Version Z or later is required to use the extension port.
For details on writing the BootOS, refer to the following manual.
GT Designer3 (GOT2000) Screen Design Manual
Wireless LAN
Set [GOT IP Address], [Subnet Mask], [Peripheral S/W Communication Port No.], and [Transparent Port No.]
for the wireless LAN interface.
2) GOT Ethernet Common Setting
Set the following setting which is common to the standard port and the extension port, or port 1 and port 2.
• [Default Gateway]
• [Peripheral S/W Communication Port No.]
• [Transparent Port No.]
3) IP Filter Setting
By configuring the IP filter setting, the access from the specific IP address can be permitted or shut off.
■1. GOT IP Address Setting
Set the GOT IP address.
(1) [Standard Port] or [Port 1]
The following shows an example for [Standard Port].
Step 1.
Select [System] → [GOT Setup] → [GOT Ethernet Setting] → [GOT IP Address Setting] → [Standard
Port] from the menu.
Step 2.
Set the followings.
Item
Update GOT Ethernet standard
port setting
GOT IP Address
Subnet Mask
Select from GOT Setting List.
Description
The GOT Ethernet standard port settings are applied on GOT.
Set the IP address of the GOT IP Address.
(Default:192.168.3.18)
Set the subnet mask for the sub network. (Only for connection via router)
If the sub network is not used, the default value is set.
(Default: 255.255.255.0)
Select the GOT set in [GOT Setting List] dialog.
GT Designer3 (GOT2000) Screen Design Manual
1.1 Setting the Communication Interface
Range
-
0.0.0.0 to 255.255.255.255
0.0.0.0 to 255.255.255.255
-
1 - 13