Mitsubishi Electric GOT2000 Series Connection Manual page 913

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

Device name
ALM215
Alarm number from Alarm History 15th alarm in past
ALM220
Alarm occurrence time in alarm history most recent alarm
ALM221
Alarm occurrence time in alarm history 1st alarm in past
ALM222
Alarm occurrence time in alarm history 2nd alarm in past
ALM223
Alarm occurrence time in alarm history 3rd alarm in past
ALM224
Alarm occurrence time in alarm history 4th alarm in past
ALM225
Alarm occurrence time in alarm history 5th alarm in past
ALM226
Alarm occurrence time in alarm history 6th alarm in past
ALM227
Alarm occurrence time in alarm history 7th alarm in past
ALM228
Alarm occurrence time in alarm history 8th alarm in past
ALM229
Alarm occurrence time in alarm history 9th alarm in past
ALM230
Alarm occurrence time in alarm history 10th alarm in past
ALM231
Alarm occurrence time in alarm history 11th alarm in past
ALM232
Alarm occurrence time in alarm history 12th alarm in past
ALM233
Alarm occurrence time in alarm history 13th alarm in past
ALM234
Alarm occurrence time in alarm history 14th alarm in past
ALM235
Alarm occurrence time in alarm history 15th alarm in past
ALM240
Detailed alarm from Alarm History most recent alarm
ALM241
Detailed alarm from Alarm History 1st alarm in past
ALM242
Detailed alarm from Alarm History 2nd alarm in past
ALM243
Detailed alarm from Alarm History 3rd alarm in past
ALM244
Detailed alarm from Alarm History 4th alarm in past
ALM245
Detailed alarm from Alarm History 5th alarm in past
ALM246
Detailed alarm from Alarm History 6th alarm in past
ALM247
Detailed alarm from Alarm History 7th alarm in past
ALM248
Detailed alarm from Alarm History 8th alarm in past
ALM249
Detailed alarm from Alarm History 9th alarm in past
ALM250
Detailed alarm from Alarm History 10th alarm in past
ALM251
Detailed alarm from Alarm History 11th alarm in past
ALM252
Detailed alarm from Alarm History 12th alarm in past
ALM253
Detailed alarm from Alarm History 13th alarm in past
ALM254
Detailed alarm from Alarm History 14th alarm in past
ALM255
Detailed alarm from Alarm History 15th alarm in past
(17) Point table
Device name
POS1 to POS255, POS1001 to POS1255
SPD1 to SPD255, SPD1001 to SPD1255
ACT1 to ACT255, ACT1001 to ACT1255
DCT1 to DCT255, DCT1001 to DCT1255
DWL1 to DWL255, DWL1001 to DWL1255
AUX1 to AUX255, AUX1001 to AUX1255
MCD1 to MCD255, MCD1001 to MCD1255
Item
Item
Point table (position)
No. 1 to 255
Point table (speed)
No. 1 to 255
Point table (acceleration time constant)
No. 1 to No. 255
Point table (deceleration time constant)
No. 1 to No. 255
Point table (dwell)
No. 1 to No. 255
Point table (auxiliary function)
No. 1 to No. 255
Point table (M code)
No. 1 to No. 255
15.6 Device Range that Can Be Set
Symbol
Symbol
15
15 - 91

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents