Mitsubishi Electric GOT2000 Series Connection Manual page 1068

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

■3. When connecting the GOT and the personal computer by Ethernet
(1) When connecting the GOT and PLC in Bus connection
The following shows the software and the accessible PLC CPUs.
QCPU (Q mode), C Controller module (Q Series)
Motion controller CPU (Q series)
MELSERVO(MR-J3-B)
MELSERVO(MR-J4-B)
*1
*2
*3
*4
*5
*6
*7
*8
(2) When connecting the GOT and PLC in direct CPU connection
The following shows the software and the accessible PLC CPUs.
FX5U, FX5UC
QCPU (Q mode)
*2
LCPU
FXCPU
Motion controller CPU (Q series)
MELSERVO(MR-J3-B)
MELSERVO(MR-J4-B)
*1
*2
*3
*4
*5
*6
*7
*8
*9
*10
*11
*12
(3) When connecting the GOT and PLC in serial communication connection
The following shows the software and the accessible PLC CPUs.
RCPU
QCPU (Q mode)
*2
LCPU
*1
*2
*3
*4
*5
*6
22 - 12
22.2 Compatible Software
PLC CPU
*5
*5
GX Works2 Version 1.48A or later is required to use the FA transparent function.
MX Component Version 3.15R or later is required to use the FA transparent function.
MX Component Version 3.15R or later is required for MX Sheet to use the FA transparent function.
Use MT Works2 Version 1.25B or later for MT Works2.
A motion controller is required between the GOT and PLC in bus connection.
Use MR Configurator2 Version 1.07H or later for MR Configurator2.
Use MR Configurator2 Version 1.09K or later for MR Configurator2.
Setting/Monitoring tool for C Controller module Version 4.00A or later is required to use the FA transparent function.
PLC CPU
*9
*9
GX Works2 Version 1.48A or later is required to use the FA transparent function.
The adapter (L6ADP-R2 or L6ADP-R4) is required.
When using L6ADP-R4, use an LCPU whose upper five digits are "15102" or later.
MX Component Version 3.15R or later is required to use the FA transparent function.
MX Component Version 3.15R or later is required for MX Sheet to use the FA transparent function.
GX Works2 Version 1.73B or later is required for GX Works2 to use the FA transparent function.
MT Works2 Version 1.25B or later is required for MT Works2 to use the FA transparent function.
MR Configurator2 Version 1.07H or later is required for MR Configurator2 to use the FA transparent function.
MR Configurator2 Version 1.09K or later is required to use the FA transparent function.
A motion controller is required between the GOT and PLC in direct CPU connection.
GX Works3 Version 1.005F or later is required to use the FA transparent function.
MX Component Version 4.11M or later is required to use the FA transparent function.
MX Sheet, please use the MX Component (Version 4.11M or later).
PLC CPU
GX Works2 Version 1.48A or later is required to use the FA transparent function.
MX Component Version 3.15R or later is required to use the FA transparent function.
MX Component Version 3.15R or later is required for MX Sheet to use the FA transparent function.
MX Component Version 4.06G or later is required to use the FA transparent function.
MX Sheet, please use the MX Component (Version 4.06G or later).
GX Works3 Version 1.030G or later is required to use the FA transparent function for the RCPU redundant system.
*1
*2
GX Works2
, MX Component
*8
module
*4
MT Works2
*6
MR Configurator2
*7
MR Configurator2
*10
*11
GX Works3
MX Component
*1
*3
GX Works2
, MX Component
*1
*3
GX Works2
, MX Component
*5
GX Works2
*6
MT Works2
*7
MR Configurator2
*8
MR Configurator2
*6
*4
GX Works3
, MX Component
, MX Sheet
*1
*2
GX Works2
, MX Component
*1
*2
GX Works2
, MX Component
Software
*3
, MX Sheet
, Setting/Monitoring tool for C Controller
Software
*12
, MX Sheet
*4
, MX Sheet
*4
, MX Sheet
Software
*5
*3
, MX Sheet
*3
, MX Sheet