Mitsubishi Electric GOT2000 Series Connection Manual page 360

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

(3) Ethernet setting
Ethernet
setting No.1
*1
■4. Checking communication state of CNC C70
(1) When using the Command Prompt of Windows.
Execute a Ping command at the Command Prompt of Windows.
(a)
When normal communication
C:\>Ping 192.168.3.19
Reply from 192.168.3.19: bytes=32 time<1ms TTL=64
(b)
When abnormal communication
C:\>Ping 192.168.3.19
Request timed out.
(2) When abnormal communication
At abnormal communication, check the followings and execute the Ping command again.
• Mounting condition of CNC C70
• Cable connecting condition
• Switch settings and network parameter settings
• Operation state of PLC CPU (faulty or not)
• IP address of the CNC C70 specified for the Ping command
5 - 94
5.4 PLC Side Setting
Item
Host
N/W No.
PLC No.
Type
IP address
*1
Port No.
*1
Communication
The following [Port No.] and [Communication format] can also be set.
[Port No.]: 5002
[Communication]: TCP
POINT
POINT
POINT
[Controller Setting] and [Ethernet] of GT Designer3
For [Controller Setting] and [Ethernet] of GT Designer3, refer to the following.
5.3.1 Setting communication interface (Controller Setting)
Set value
*
239
2
Q17nNC
192.168.1.2
5001
UDP

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents