(2) Station information setting
Station type
Exclusive station count
Reserve/invalid station select
Intelligent buffer select (word)
*1
*2
■3. [Controller Setting] of GT Designer3
Station No.
Transmission Rate
Mode
Expanded Cyclic
Number of stations occupied
Input for Error Station
Retry
Timeout Time
Delay Time
Transmission method
12 - 50
12.4 PLC Side Setting
*1
Item
*2
When the [Mode] of the CC-Link module is set at [Remote net - (Ver. 1 mode)], [Remote station points] cannot be set.
Set the same setting as that of the GOT.
POINT
POINT
POINT
When changing the network parameter
After writing the network parameter to the PLC CPU, operate the PLC CPU ether turning OFF
and then ON or resetting.
Item
POINT
POINT
POINT
[Controller Setting] of GT Designer3
For the setting method of [Controller Setting] of GT Designer3, refer to the following.
12.3.1 Setting communication interface (Controller Setting)
Set value
Intelligent device station (fixed)
Exclusive station 1
No setting
(Use default value)
: Necessary
Set value
1: Station No.1
0: Online 156kbps
Ver.1: Remote net (Ver.1 mode)
Single (Use default value)
1 Station
0: Clear
3times (Use default value)
3sec (Use default value)
0ms (Use default value)
MELSEC (compatible)
Setting necessity at GOT
connection
: As necessary
: Not necessary