Connecting To Peripheral I/F (Built-In Ethernet Port Motion Controller Cpu) - Mitsubishi Electric GOT2000 Series Connection Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

5.2.5
Connecting to PERIPHERAL I/F (Built-in Ethernet port Motion
Controller CPU)
Q172DCPU-S1
PLC
Q173DCPU-S1
Q172DSCPU
CPU
Q173DSCPU
Q170MCPU
Q170MSCPU
Q170MSCPU-S1
MR-MQ100
PLC
*2
Model name
Motion controller CPU
(Q Series)
Q172DCPU-S1
Q173DCPU-S1
Q172DSCPU
Q173DSCPU
Q170MCPU
Q170MSCPU
Q170MSCPU-S1
MR-MQ100
*1
*2
*3
*4
5 - 18
5.2 System Configuration
Connection cable
Connection cable
Communication
type
• 100BASE-TX
Shielded twisted pair cable (STP) or
unshielded twisted pair cable (UTP)
of category 5 or higher
Ethernet
• 10BASE-T
Shielded twisted pair cable (STP) or
unshielded twisted pair cable (UTP)
of category 3 or higher
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver or other system equipment corresponding to the applicable Ethernet network
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standard.
When using the PERIPHERAL I/F, set as shown below.
• Use the GT Designer3 Version1.12N or later.
• Select [QnUDE(H)] for [Controller Type] in [Ethernet] of GT Designer3.
For [Ethernet] of GT Designer3, refer to the following.
5.3.4 Ethernet setting
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
GT25-W, GT2505-V does not support the option device.
POINT
POINT
POINT
Monitoring other station
When connecting with PERIPHERAL I/F, the GOT cannot be monitoring other station.
POINT
POINT
POINT
Direct connection between PERIPHERAL I/F and GOT
The PERIPHERAL I/F and GOT can be directly connected by using a cross cable for the
Ethernet connection cable.
GOT
Maximum
segment
*1
Option device
*3
length
- (Built into GOT)
30m
GT25-J71E71-100
Communication driver
Ethernet(MELSEC),Q17nNC,
CRnD-700,Gateway
GOT
Number of
connectable
*4
Model
equipment
16 GOTs for 1
network