The following connection methods are available for the QCPU redundant system.
• Connection to remote I/O station in MELSECNET/H network system
Direct CPU connection (Remote I/O station of MELSECNET/H network system)
• Serial communication connection (Serial communication module mounted on remote I/O station of MELSECNET/H
network system)
• Ethernet connection (Ethernet module mounted on the remote I/O station of the MELSECNET/H network system)
• Direct CPU connection
• CC-Link connection (intelligent device station)
• CC-Link connection (Via G4)
• MELSECNET/H connection, MELSECNET/10 connection (Network system)
• CC-Link IE Controller Network connection (Network system)
• Ethernet connection
• Connection to the redundant type extension base unit
Serial communication connection (Serial communication module mounted on the redundant type extension base unit)
Ethernet connection (Ethernet module mounted on the redundant type extension base unit)
CC-Link connection (intelligent device station) (CC-Link module mounted on the redundant type extension base unit)
CC-Link connection (Via G4) (CC-Link module mounted on the redundant type extension base unit)
For details of PLC CPUs that can be monitored in each connection method of GOT, refer to the following.
4 - 50
4.2 MELSEC Q Series
■1.Direct CPU connection (Direct CPU connection to the remote I/O station)
■2.Serial communication connection (Connection to serial communication module mounted on
remote I/O station)
■3.Ethernet connection (Connection to Ethernet module mounted on remote I/O station)
4.2.2Direct CPU Connection
4.2.3CC-Link Connection (Intelligent Device Station)
4.2.4CC-Link Connection (Via G4)
4.2.5MELSECNET/H and MELSECNET/10 Connections (Network Systems)
4.2.6CC-Link IE Controller Network Connection (Network System)
4.2.7Ethernet Connection
■1.Serial communication connection (Connection to the Serial communication module mounted
on the redundant type extension base unit)
■2.Ethernet connection (Connection to the Ethernet module mounted on redundant type
extension base unit)
■3.CC-Link connection (intelligent device station) (Connection to the CC-Link module mounted on
redundant type extension base unit)
■4.CC-Link connection (Via G4) (Connection to the CC-Link module mounted on redundant type
extension base unit)
Monitorable controllers of each chapter