Mitsubishi Electric GOT2000 Series Connection Manual page 1061

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

(2) When connecting the GOT and PLC in direct CPU connection
The following shows the software and the accessible PLC CPUs.
PLC CPU
FX5U, FX5UC
QCPU (Q mode)
*15
LCPU
QCPU (A mode), QnA/ACPU,
motion controller CPU (A Series)
FXCPU
Motion controller CPU (Q Series)
FREQROL A700/F700/E700/D700 Series
Sensorless servo (FREQROL E700EX)
Robot controller (CRnQ-700)
*16
MELSERVO(MR-J3-B)
*16
MELSERVO(MR-J4-B)
*1
MELSOFT Navigator Version 1.71Z or later is required to use the FA transparent function.
*2
GX Works2 Version 1.497T or later is required to use the FA transparent function.
*3
PX Developer Version 1.40S or later is required to use the FA transparent function.
*4
MX Component that you can use the FA transparent function is scheduled to be supported soon.
*5
The MX Sheet, please use the MX Component (will be supported soon).
*6
GX LogViewer Version 1.32J or later is required to use the FA transparent function.
*7
CPU Module Logging Configuration Tool Version 1.32J or later is required to use the FA transparent function.
*8
The adapter (L6ADP-R2 or L6ADP-R4) is required.
When using L6ADP-R4, use an LCPU whose upper five digits are "15102" or later.
*9
FX Configurator-FP that you can use the FA transparent function is scheduled to be supported soon.
*10
FX3U-ENET-L Configuration tool that you can use the FA transparent function is scheduled to be supported soon.
*11
MT Developer Version 1.66U or later is required to use the FA transparent function.
*12
FR Configurator that you can use the FA transparent function is scheduled to be supported soon.
*13
RT ToolBox2 Version 3.00 or later is required to use the FA transparent function.
*14
Start MR Configurator2 with MT Developer2 Version 1.66U or later.
*15
MR Configurator2 Version 1.24A or later is required to use the FA transparent function.
*16
A motion controller is required between the GOT and PLC in direct CPU connection.
*17
GX Works3 Version 1.005F or later is required to use the FA transparent function.
*18
GX Developer Version 8.118Y or later is required to use the FA transparent function.
*19
MX Component Version 4.11M or later is required to use the FA transparent function.
*20
MX Sheet, please use the MX Component (Version 4.11M or later).
*17
*19
GX Works3
,MX Component
,MX Sheet
*1
MELSOFT Navigator
*2
GX Works2
*3
PX Developer
*18
GX Developer
*4
*5
MX Component
,MX Sheet
*6
GX Logviewer
CPU Module Logging Configuration Tool
*1
MELSOFT Navigator
*2
GX Works2
*18
GX Developer
*4
*5
MX Component
,MX Sheet
,
*6
GX Logviewer
CPU Module Logging Configuration Tool
*18
GX Developer
*4
*5
MX Component
,MX Sheet
*1
MELSOFT Navigator
*2
GX Works2
*18
GX Developer
*9
FX Configurator-FP
*10
FX3U-ENET-L Configuration tool
*4
*5
MX Component
,MX Sheet
*1
MELSOFT Navigator
*11
*4
MT Works2
, MX Component
, MX Sheet
*12
FR Configurator
*12
FR Configurator
*13
RT ToolBox2
, RT ToolBox3
*14*15
MR Configurator2
*14*15
MR Configurator2
Software
*20
*7
*7
*5
22.2 Compatible Software
22
22 - 5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents