Mitsubishi Electric GOT2000 Series Connection Manual page 599

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

■3. Parameter settings (Connecting to MELSEC iQ-R series) of System configuration1
(Network Type: CC IE Control)
(1) [Module parameter] of CW Configurator
(a)
Module parameter
Station type
*1
Network No.
Station number setting
Network range assignment
Channel No.
*1
Specify the same network No. as that of the GOT.
(b)
Network range assignment
LB/LW setting
*1
(1)
*1
LB/LW setting (2)
*1
LX/LY setting (1)
*1
LX/LY setting (2)
Reserved station
Pairing
*1
Be sure to set it to perform the cyclic transmission.
Item
Item
Start
Station No.1
End
LB
Start
Station No.2
End
Start
Station No.1
End
LW
Start
Station No.2
End
Set value
Control station (fixed)
1
1
Refer to (b)
(Use default value)
: Necessary
: As necessary
Set value
0000H
00FFH
0100H
01FFH
00000H
000FFH
00100H
001FFH
No setting
No setting
No setting
(Use default value)
: Necessary
: As necessary
10.4 PLC Side Setting
Setting necessity at GOT connection
: Not necessary
Setting necessity at GOT connection
: Not necessary
10 - 21
10