Connecting to CC-Link IE Field Network Ethernet Adapter Module

This section describes the settings of the GOT, Ethernet adapter module and the PLC in the following system configuration.
■1. System configuration
*1
Set the GOT network No. according to the third octet (network No.) of the Ethernet adapter module IP address.
*2
The CC-Link IE Field Network Master/Local module is mounted on slot 0 of the base unit.
The start I/O No. of the CC-Link IE Field Network Master/Local module is set at [0].
<GOT>
(Use default value for settings other than the following.)
Network No.
PC No.
IP address
Port No.
Communication
format
Ethernet
<Ethernet adapter module>
(Use default value for settings other than the following.)
Ethernet setting
IP address
:192.168.3.30
CC-Link IE Field Network setting
Network No.
:1
Station No.
:1
CC-Link IE Field Network
HUB
<CC-Link IE Field Network Master/Local module>
(Use default value for settings other than the following.)
Network Type
: CC IE Field (Master station)
Network No.
: 1
PC No.
: 0
Total Stations
: 2
<CC-Link IE Field Network Master/Local module>
(Use default value for settings other than the following.)
Network Type
: CC IE Field (Local station)
Network No.
: 1
PC No.
: 2
*1
:3
:1
:192.168.3.18
:5001
:UDP (fixed)
*2
*2
5.4 PLC Side Setting