Station Number Setting - Mitsubishi Electric GOT2000 Series Connection Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

14.2.9

Station number setting

Set each station number so that no station number overlaps.
The station number can be set without regard to the cable connection order. There is no problem even if station numbers
are not consecutive.
■1. Direct specification
When setting the device, specify the station number of the inverter of which data is to be changed.
■2. Indirect specification
When setting the device, indirectly specify the station number of the inverter of which data is to be changed using the
16-bit GOT internal data register (GD10 to GD25).
When specifying the station No. from 100 to 155 on GT Designer3, the value of GD10 to GD25 compatible to the
station No. specification will be the station No. of the inverter.
Specification station NO.
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
14 - 44
14.2 System Configuration
Station
Station
No.3
No.0
GOT
Examples of station number setting
Specification range
Compatible device
GD10
GD11
GD12
GD13
GD14
GD15
GD16
0 to 31
GD17
For the setting other than the above, error (dedicated device is out of range) will
GD18
occur.
GD19
GD20
GD21
GD22
GD23
GD24
GD25
Station
Station
Station
No.1
No.21
No.6
0 to 31
Setting range

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents