3. ACCESS RANGE FOR MONITORING
3.1

Access Range for Monitoring Stations on Network Systems

3.1.1
MELSECNET/H, MELSECNET/10, CC-Link IE Controller Network, CC-
Link IE Field Network
■1. Bus connection
(1) When connecting to multiple CPU system
• The GOT can monitor the control station and all the normal stations on the network.
• The GOT can monitor the control station and all the normal stations on other networks.
(For monitoring stations on other networks, be sure to set the routing parameter)
When the Universal model QCPU is used as a relay station, the GOT can monitor stations with the station No.65 or
later in the CC-Link IE controller network.
• When connecting to the multiple CPU system, the GOT can monitor CPU No.1 to No.4.
• Devices of other stations (other than devices B and W that are allocated by the network parameter) may not allow
monitoring depending on their PLC CPU.
➠ ■7.
• The motion controller CPU (Q Series) at other stations cannot be monitored.
*1
3 - 2
3.1 Access Range for Monitoring Stations on Network Systems
GOT
GOT
Monitor accessible range of other stations and setting method of monitor devices (Examples
1 to 2)
The control station and normal station correspond to the master station and local station in the CC-Link IE field network
respectively.
Control station
GOT
*1
Normal
Normal
station
station
Normal
station
Control station
Control
station
Normal
Normal
station
station
Normal
Normal
station
station
Control station
Control
station
Normal
Normal
station
station
Normal
station
Normal station
*1
Normal
station
Normal
station

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents