Mitsubishi Electric GOT2000 Series Connection Manual page 947

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

■2. Expansion unit settings
(1) FCU6-EX879 (Optical fiber cable)
No.
Switch name
Condition setting
switch
8
7
6
5
1)
4
3
2
1
ON
Station number setting
switch
2)
Setting switch of group
number
3)
Setting switch of
network number
4)
Mode setting switch
5)
*1
Set the network type to the PLC to PLC network.
*2
Set as necessary.
*3
Set the station No. not to overlap with that of other units.
*4
Set the station type to the control station.
For details of the parameter setting, refer to the following.
Set the operation condition.
SW
Description
*1
1
Network type
*4
2
Station type
*2
3
Used parameter
4
*2
Number of stations
(Valid when SW3 is ON)
5
6
*2
B/W total points
(Valid when SW3 is ON)
7
8
Not used
*2*3
Station number setting
(Setting range)
01 to 64: Station number
Other than 01 to 64: Setting error
Group number setting
Not used, fixed to 0
*2
Network number setting
(Setting range)
001 to 255: Network number
Other than 001 to 255: Setting error
*2
Mode setting
0: Online
1: Cannot be used
2: Offline
3 to F: Test mode
C6/C64/C64T NETWORK INSTRUCTION MANUAL BNP-B2373
Settings
OFF
Inter-PC net (PC)
Normal station (N.ST)
Common parameters (PRM)
OFF
ON
8
16
Station
Station
OFF
OFF
OFF
ON
2K
4K
points
points
OFF
OFF
Always OFF
17.5 CNC Side Settings
ON
Remote I/O net
Control station (MNG)
Default parameter (D.PRM)
OFF
ON
32
64
Station
Station
ON
ON
OFF
ON
6K
8K
points
points
ON
ON
17 - 17
17