Time And Sntp Commands - Panasonic ZEQUO 2200 Operating Instructions Manual

Switching hub
Table of Contents

Advertisement

61. Time and SNTP Commands

61.Time and SNTP Commands
The commands are used to set the time for the internal clock of this
Switching Hub.
The time can be set manually or automatically using SNTP (Simple
Network Time Protocol).
You can also configure the time zone and summer time settings.
config sntp {primary <ipaddr> | secondary <ipaddr> | poll-interval <int 30-99999>} (1)
show sntp
enable sntp
disable sntp
config time <date ddmthyyyy> <time hh:mm:ss>
config time_zone {operator [+ | -] | hour <gmt_hour 0-13> | min <minute 0-59>} (3)
config dst [disable | repeating {s_week <start_week 1-4,last> | s_day <start_day sun-sat> | s_mth
<start_mth 1-12> | s_time <start_time hh:mm> | e_week <end_week 1-4, last> | e_day
<end_day sun-sat> | e_mth <end_mth 1-12> | e_time <end_time hh:mm> | offset [30 | 60 |
90 | 120]} (9) | annual {s_date <start_date 1-31> | s_mth <start_mth 1-12> | s_time
<start_time hh:mm> | e_date <end_date 1-31> | e_mth <end_mth 1-12> | e_time <end_time
hh:mm> | offset [30 | 60 | 90 | 120]}(7)]
show time
61.1. config sntp
 Description
This command is used to change SNTP configurations.
 Format
config sntp {primary <ipaddr> | secondary <ipaddr> | poll-interval <int 30-99999>} (1)
 Parameters
primary (Optional) Specify the SNTP primary server IP address.
<ipaddr>
secondary
(Optional) Specify the SNTP secondary server IP address.
<ipaddr>
poll-interval
(Optional) Specify the polling interval range.
<int 30-99999> Specify the polling interval range between 30 and 99999 seconds.
 Restrictions
Specify the SNTP primary server IP address.
Specify the SNTP secondary server IP address.
574