5.13. config serial_port
 Description
This command is used to configure the serial bit rate that will be used to communicate with
the management host and the auto logout time for idle connections.
 Format
config serial_port {baud_rate [9600 | 19200 | 38400 | 9600] | auto_logout [never |
2_minutes | 5_minutes | 10_minutes | 15_minutes]}(1)
 Parameters
baud_rate
Specify the baud rate value. The default baud rate is 9600.
9600 Specify a baud rate of 9600.
19200
Specify a baud rate of 19200.
38400
Specify a baud rate of 38400.
115200
Specify a baud rate of 115200.
auto_logout
Specify the timeout value. The default timeout is 10_minutes.
never Specify to never timeout.
2_minutes
Specify when the idle value is over 2 minutes, the device will auto logout.
5_minutes
Specify when the idle value is over 5 minutes, the device will auto logout.
10_minutes
Specify when the idle value is over 10 minutes, the device will auto logout.
15_minutes
Specify when the idle value is over 15 minutes, the device will auto logout.
 Restrictions
Only Administrator and Operator-level users can issue this command.
 Example
To configure the baud rate:
Zxxx0:admin# config serial_port baud_rate 9600
Command: config serial_port baud_rate 9600
Success.
Zxxx0:admin#
5. Basic Management Commands