Config Temperature Threshold - Panasonic ZEQUO 2200 Operating Instructions Manual

Switching hub
Table of Contents

Advertisement

state
Enable or disable either the trap or log state for a warning temperature event. The
default is enable.
enable
Enable either the trap or log state for a warning temperature event.
disable
Disable either the trap or log state for a warning temperature event.
 Restrictions
Only Administrator and Operator-level users can issue this command.
 Example
To enable the warning temperature trap state:
Zxxx0:admin#config temperature trap state enable
Command: config temperature trap state enable
Success.
Zxxx0:admin#
To enable the warning temperature log state:
Zxxx0:admin#config temperature log state enable
Command: config temperature log state enable
Success.
Zxxx0:admin#

5.11. config temperature threshold

 Description
This command is used to configure the warning temperature high threshold or low
threshold. When temperature is above the high threshold or below the low threshold, SW
will send alarm traps or keep the logs.
 Format
config temperature threshold {high <temperature -500-500> | low <temperature -500-
500>}(1)
 Parameters
high
Specify the high threshold value. The high threshold must bigger than the low threshold.
<temperature -500-500>
Specify the high threshold value. This value must be between -500 and 500.
5. Basic Management Commands
37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pn26241Zequo 2210 pn26161

Table of Contents