17. Didital Diagnostic Monitoring (DDM) Commands
17.5. config ddm ports rx_power_threshold
 Description
This command is used to configure the thresholds of the output power of the specified
ports. The command configures the bias current thresholds of the specified ports. The
precision of the effective threshold is dependent on the hardware.
 Format
config ddm ports [<portlist> | all] tx_power_threshold { high_alarm < mw_or_dbm > |
low_alarm < mw_or_dbm > | high_warning < mw_or_dbm > |
low_warning < mw_or_dbm > } (1))
 Parameters
ports
<portlist>
Specifies a range of ports to be configured. (The portlist format: UnitID: port
number).
all
If 'all' parameter is chosen, all optic ports' operating parameters will be configured.
tx_power_threshold
Specifies the threshold of the optic module's output power.
high_alarm
<mw_or_dbm>
Specifies the high threshold for the transmit power alarm.
When the operating parameter rises above this value, the action associated with
alarm is taken.
If the unit is mW, the range of this parameter is from 0 to 6.5535mW. If the unit is
dBm, the range of this parameter is form -40 to 8.1647dBm.
low_alarm
<mw_or_dbm>
Specifies the low threshold for the transmit power alarm.
When the operating parameter falls below this value, the action associated with
the alarm is taken.
If the unit is mW, the range of this parameter is from 0 to 6.5535mW. If the unit is
dBm, the range of this parameter is form -40 to 8.1647dBm.
high_warning
<mw_or_dbm>
Specifies the high threshold for the transmit power warning.
When the operating parameter rises above this value, the action associated with
the warning is taken.
If the unit is mW, the range of this parameter is from 0 to 6.5535mW. If the unit is
dBm, the range of this parameter is form -40 to 8.1647dBm.