12. BPDU Attack Protection Commands
12.6. show bpdu_protection
 Description
This command is used to display BPDU protection global configuration or per port
configuration and current status.
 Format
show bpdu_protection {ports {<portlist>}}
 Parameters
ports
(Optional) Specify all ports to be displayed.
<portlist>
(Optional) Specify a range of ports to be displayed.
 Restrictions
 None.
 Example
To display BPDU protection information for the entire Switching Hub:
Zxxx0:admin#show bpdu_protection
Command: show bpdu_protection
BPDU Protection Global Settings
---------------------------------------
BPDU Protection Status
BPDU Protection Recover Time
BPDU Protection Trap State
BPDU Protection Log State
Zxxx0:admin#
To display BPDU protection status for ports 1 to 3:
Zxxx0:admin#show bpdu_protection ports 1-3
Command: show bpdu_protection ports 1-3
Port
State
----- -----------
1
Disabled
Shutdown
2
Disabled
Shutdown
3
Disabled
Shutdown
Zxxx0:admin#
: Disabled
: 60 seconds
: None
: Both
Mode
Status
---------- -----------
Normal
Normal
Normal
112