17. Didital Diagnostic Monitoring (DDM) Commands
17.3. config ddm ports
bias_current_threshold
 Description
This command is used to configure the thresholds of bias current of the specified ports.
The command configures the bias current thresholds of the specified ports. The precision
of the effective threshold is dependent on the hardware.
 Format
config ddm ports [<portlist> | all] bias_current_threshold { high_alarm < milliampere >|
low_alarm < milliampere > | high_warning < milliampere > |
low_warning < milliampere > } (1)
 Parameters
ports
<portlist>
Specifies a range of ports to be configured. (The portlist format: UnitID: port
number).
all
If 'all' parameter is chosen, all optic ports' operating parameters will be configured.
bias_current_threshold
Specifies the threshold of the optic module's bias current.
high_alarm
<milliampere>
Specifies the high threshold for the bias current alarm.
When the operating parameter rises above this value, the action associated with
the alarm is taken. The range of this parameter is from 0 to 131mA.
low_alarm
<milliampere>
Specifies the low threshold for the bias current alarm.
When the operating parameter falls below this value, the action associated with
the alarm is taken. The range of this parameter is from 0 to 131mA
high_warning
<milliampere>
Specifies the high threshold for the bias current warning.
When the operating parameter rises above this value, the action associated with
the warning is taken. The range of this parameter is from 0 to 131mA
low_warning
<milliampere>
Specifies the low threshold for the bias current warning.
When the operating parameter falls below this value, the action associated with
the warning is taken. The range of this parameter is from 0 to 131mA