Hitachi Compute Blade 2000 User Manual page 433

Hide thumbs Also See for Compute Blade 2000:
Table of Contents

Advertisement

2
Select a hard disk with the Offline status, check Rebuild, and click Go.
The rebuilding progress is displayed.
3
Wait until the processing is completed 100%.
A guideline for rebuilding time is shown in the table below.
RAID level
Capacity of a disk array
RAID 1
300 GB (SAS: 300 GB HDD x 2)
200 GB (SAS: 200 GB SSD x 2)
RAID 5
600 GB (SAS: 300 GB HDD x 3)
400 GB (SAS: 200 GB SSD x 3)
RAID 6
600 GB (SAS: 300 GB HDD x 4)
400 GB (SAS: 200 GB SSD x 4)
RAID 10
600 GB (SAS: 300 GB HDD x 4)
400 GB (SAS: 200 GB SSD x 4)
The rebuilding time is proportional to the capacity of a disk
array.
4
When rebuilding is completed 100%, click Home to return to the main menu.
Rebuilding time
Approximately 40 minutes
Approximately 10 minutes
Approximately 40 minutes
Approximately 10 minutes
Approximately 40 minutes
Approximately 10 minutes
Approximately 40 minutes
Approximately 10 minutes