Select a menu item you require from the following list, and execute it.
Menu
S.
Shutdown.
R.
Restart.
SW.
Switch active/standby.
Q.
Quit.
Do not perform Shutdown and Restart on the management
module while the server blade is operating. Error events,
which have occurred while the management module is
restarting or shutting down, may not be detected.
When restarting and shutting down a management module
while the server blade with N+M cold standby enabled is not
in operation, make sure to perform Smart Configure
afterwards.
If you enter L in the MMC command menu and press Enter; the identification LED
menu is displayed.
(P,L,[Q]) : L
(Enter)
-- Management module status --
M Behavior Power Condition LID lamp
- -------- ----- ------------- --------
0
------
---
1 Active
On
Normal
-- LID lamp control menu --
T. Turn on
F. Turn off
Q. Quit.
(T,F,[Q]) :
Select a menu item you require from the following list, and execute it.
Menu
T.
Turn on
F.
Turn off
Q.
Quit.
Shuts down the management module.
Restarts the management module.
Switches between the active and standby management
modules.
Returns to the previous menu.
-----------
------
Off
Turns on the identifying LED of the management module.
Turns off the identifying LED of the management module.
Returns to the previous menu.