9
Some configured disks have been removed from
your system, or are no longer accessible. Check
your cables and also ensure all disks are present.
Press any key to continue or press C to load the
configuration utility.
10
The following VDs have missing disks:
- If you proceed (or load the configuration utility),
these VDs will be marked OFFLINE and will be
inaccessible.
- Check your cables and ensure all disks are
present.
Press any key to continue or press C to load the
configuration utility.
11
A discovery error has occurred. Power-cycle the
system and all the enclosures attached to this
system.
12
The following VDs are missing:
If you proceed ( or load the configuration utility),
these VDs will be removed from your
configuration. If you wish to use them at a later
time, they will have to be imported. If you decide
these VDs should be present, power off your
system and check your cables to ensure all disks
are present. Press any key to continue or press C
to load the configuration utility.
13
The following VDs are missing complete spans. If
you proceed (or load the configuration utility),
these VDs will be removed from your
configuration and the remaining drives marked as
foreign.
If you wish to use them at a later time, restore the
missing spans and use foreign import to recover
the VDs. If you believe these VDs should be
present, please power off your system and check
your cables to ensure all disks are present. Press
any key to continue, or 'C' to load the
configuration utility.
14
All of the disks from your previous configuration
are gone. If this is an unexpected message, then
power off your system and check your cables to
ensure all disks are present. Press any key to
continue or press C to load the configuration
utility.
15
Your battery is either charging, bad, or missing,
and you have VDs configured for write-back
mode. Because the battery is not currently
usable, these VDs will actually run in the write-
through mode until the battery is fully charged or
replaced if it is bad or missing. Press any key to
continue.
Message
396
Description
Some hard disks with the disk array configuration
information have been removed. When this
message is displayed even if the device is installed
properly, contact your reseller or call maintenance
personnel.
Since some hard disks have been removed, the
disk array is set in OFFLINE.
When this message is displayed even if the device
is installed properly, contact your reseller or call
maintenance personnel.
A disk array controller or hard disk has not been
recognized correctly. When this message is
displayed, contact your reseller or call
maintenance personnel.
Some disk array configurations are removed.
When this message is displayed even if the device
is installed properly, contact your reseller or call
maintenance personnel.
All hard disks with disk array configuration
information have been removed.
When this message is displayed even if the device
is installed properly, contact your reseller or call
maintenance personnel.
Cache backup module information is not correct.
When this message is displayed even if the device
is installed properly, contact your reseller or call
maintenance personnel.